American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 72 / Number 3

A 2D(γ,n)1H Tritiated Water Detector with 232U/228Th Source

Norman P. Baumann, Willard G. Winn

Nuclear Technology / Volume 72 / Number 3 / March 1986 / Pages 353-358

Technical Paper / Radiation Protection and Health Physics Practices and Experience in Operating Reactors Internationally / Analyse / dx.doi.org/10.13182/NT86-A33774

A long-lived gamma source, containing 370 MBq of 232U (72 yr) and 110 MBq of 228Th (1.9 yr), was developed as a permanent replacement for neutron-activated 24Na (15-h) sources that have been used in a 2D(γ,n)1H tritiated water detector. The 228Th, which will build up to 340 MBq in 10 yr and then decay in equilibrium with 232U, emits copious 2614-keV gamma rays for the (γ, n) process. Competing (α, n) backgrounds are reduced by placing the uranium/thorium source in a gold matrix to provide threshold and coulomb barriers against the reaction. The detection limits (∼0.0l-ml D2O) for typical stainless steel pipes (∼2-cm diam) measured with the uranium/thorium source are almost as low as those for comparable 24Na sources, which do not produce (α,n) backgrounds. This minor sensitivity loss can be offset by longer counting times, if necessary. Lower personnel exposure is realized with the new source. Overall, the practical advantages of using a longer lived source strongly favor the use of 232U/228Th instead of 24Na.