American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 168 / Number 2

Monte Carlo Calculations for the Shielding Design of Beam Injection and Extraction Areas at the 3-GeV Synchrotron in J-PARC

Yoshihiro Nakane, Teruo Abe, Hiroshi Nakashima

Nuclear Technology / Volume 168 / Number 2 / November 2009 / Pages 519-523

Shielding / Special Issue on the 11th International Conference on Radiation Shielding and the 15th Topical Meeting of the Radiation Protection and Shielding Division (Part 2) / Accelerators / dx.doi.org/10.13182/NT09-A9236

Radiation shielding calculations were performed for the shielding design around beam injection and beam extraction areas at the 3-GeV proton synchrotron in the Japan Proton Accelerator Research Complex (J-PARC) with the PHITS Monte Carlo code. Prompt dose rates outside the shields were obtained from calculated neutron energy spectra and flux-to-dose conversion coefficients prepared for the shielding design in J-PARC. The thicknesses of shields were determined from the comparison results of the prompt dose rates with the criteria of dose limit for the design in J-PARC.