American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 168 / Number 1

Evaluation of Skyshine Dose for the Proton Accelerator Facility of the Proton Engineering Frontier Project in Korea

Cheol Woo Lee, Young-Ouk Lee, Young-Sik Cho

Nuclear Technology / Volume 168 / Number 1 / October 2009 / Pages 144-148

Dose/Dose Rate / Special Issue on the 11th International Conference on Radiation Shielding and the 15th Topical Meeting of the Radiation Protection and Shielding Division (Part 1) / Dosimetry / dx.doi.org/10.13182/NT09-A9115

Evaluation of the skyshine dose for the proton linac facility of the Proton Engineering Frontier Project in Korea was performed in this study. To predict the skyshine dose level outside of the facility, a Monte Carlo method (MCNPX code), analytical method using an estimation formula, and SKYSHINE-KSU codes using an integral line-beam method were considered in the evaluations. The neutron spectrum at the outer surface of the roof of the facility was considered as the radiation source term. The results from each method were in good agreement for the distance from 200 to 1000 m. The neutron dose of 1.65 × 10-4 Sv/h is expected at the fence of the facility, which is 400 m from the accelerator room.