Home / Publications / Journals / Nuclear Technology / Volume 211 / Number 2
Nuclear Technology / Volume 211 / Number 2 / February 2025 / Pages 258-272
Research Article / dx.doi.org/10.1080/00295450.2024.2324513
Articles are hosted by Taylor and Francis Online.
The fundamental prompt neutron delayed constant , and the effective neutron generation time
are important for accurate measurements of keff in subcritical systems. In this paper, based on the open-source program OpenMC, a module with the function of calculating the
, and
) of the subcritical system and allowed for a more accurate keff under the subcritical system as compared to the traditional k-mode program.
In this paper, the results of the and
was verified with the KUCA (Kyoto University Critical Assembly) benchmark. The results of the keff calculations using k-mode and
The results show that the calculation program (α-mode) can obtain keff under the subcritical system more accurately, which makes up for the shortcomings of the traditional program, which cannot be calculated under the deep subcritical system. The relative error between the calculated and reference values was less than 750 pcm at deep subcriticality (keff = 0.899). The error was less than 400 pcm at the deeper subcritical system (keff = 0.952), which can satisfy the demand for neutron dynamics parameters and keff calculation in the subcritical system. The program can also continue to be upgraded in the later stage in the calculation method and other aspects.