American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 210 / Number 11

Validation of EPG/SAG Rev. 4 of the Kuosheng Nuclear Power Plant Using the MAAP5 Code

Yu-Min Chen, Te-Chuan Wang, Min Lee

Nuclear Technology / Volume 210 / Number 11 / November 2024 / Pages 2017-2037

Research Article / dx.doi.org/10.1080/00295450.2024.2306693

Received:September 28, 2023
Accepted:January 12, 2024
Published:September 25, 2024

The Boiling Water Reactor Owner’s Group released Emergency Procedure Guidelines and Severe Accident Guidelines Revision 4 (EPG/SAG Rev. 4) in 2018. The major improvement to EPG/SAG Rev. 4 was Contingency 1 (Alternate Level/ Pressure Control). Contingency 1 coordinates the reactor pressure vessel (RPV) water level and RPV pressure control action to prolong the availability of steam-driven injections and optimize the transfer to motor-driven systems.

In this study, the effectiveness of the EPG/SAG Rev. 4 Contingency 1 strategy was compared with those of EPG/SAG Revision 2 Contingency 1 and Specific Major Incident Guidelines (SMI) using the Modular Accident Analysis Program, Version 5 (MAAP5). SMI was developed by the Taiwan Power Company to mitigate a Fukushima-like accident. The surrogate plant that analyzed is the Kuosheng Nuclear Power Plant (NPP). The Kuosheng NPP is BWR-6 Mark-III containment. MAAP5 is an integral severe accident analysis program that simulates the responses of a light water reactor power plant during a severe accident. This program has been used extensively for probabilistic risk assessments and for verification and validation of mitigation actions specified in severe accident management guidelines.

The simulation scenarios were extended loss of alternative-current power and loss of ultimate heat sink. The low-capacity, motor-driven portable pump was the only available system for RPV injection in the first hour of the accident. In this time period, the RPV water level and pressure were controlled by reactor core isolation cooling and safety relief valves. After this study, the strategy of EPG/SAG Rev. 4 Contingency 1 was successfully validated, and the effectiveness of minimum pre-depressurization RPV water level and the low-capacity, motor-driven portable pump were also demonstrated in this study.