Assessment of Screen-Covered Grooved Sodium Heat Pipes for Microreactor Applications

Donna Post Guillen, Clayton G. Turner

Nuclear Technology / Volume 208 / Number 8 / August 2022 / Pages 1301-1310

Technical Paper / dx.doi.org/10.1080/00295450.2021.1977085

Received:March 31, 2021
Accepted:September 2, 2021
Published:July 11, 2022

New nuclear reactor designs that incorporate heat pipes are being investigated for possible near-term deployment in terrestrial applications. This study explores the use of screen-covered axially grooved sodium heat pipes and their applicability for providing heat removal for microreactors. A sodium working fluid is appropriate for microreactors operating in the 5 to 20 MW(thermal) range at approximately 650°C. HTPIPE, a legacy software code, was validated for the case of screen-covered grooves and used to perform steady-state analyses to determine the performance limits of a proposed heat pipe design. The performance limits of a sodium heat pipe with a screen-covered square grooved wick structure is compared to that of an equivalent heat pipe with an annular wick. In a horizontal orientation at an operating temperature of 650°C,the performance limits for the heat pipe with an annular wick configuration are 15% higher than for the screen-covered grooved wick. At operating temperatures below 777°C, the annular wick outperforms the screen-covered grooved wick, and at temperatures above 777°C, the screen-covered grooved wick outperforms the annular wick. However, the marginal performance gain at higher temperatures may not justify the use of heat pipes with a screen-covered grooved wick structure due to increased manufacturing costs.