The CRANK System—A Simple, Robust Apparatus for Measurement of Cherenkov Light at Open-Pool Reactor

Thomas V. Holschuh, Wade R. Marcum

Nuclear Technology / Volume 206 / Number 3 / March 2020 / Pages 428-434

Technical Paper / dx.doi.org/10.1080/00295450.2019.1640515

Received:March 20, 2019
Accepted:July 2, 2019
Published:January 31, 2020

Recently, techniques for qualitative inspections of spent fuel using Cherenkov light have advanced the International Atomic Energy Agency’s ability to perform defect verification measurements following discharge of the fuel from the reactor. Unfortunately, these measurements are limited in their value for safeguards and nuclear material accountancy since they do not quantify the fissile material quantities and cannot characterize a reactor during operations. The Cherenkov Radiation Assay for Nuclear Kinetics (CRANK) system has been devised to quantify the fissile material in the Oregon State TRIGA Reactor (OSTR) during two or more reactor pulses through the measurement of Cherenkov light. The results from the OSTR experiments have shown that the CRANK system is capable of determining the ratio of reactor kinetics parameters (RKP) through the measurement of Cherenkov light in an assay of a research reactor capable of pulsing. There exists excellent agreement between the declared value of the RKP ratio in the OSTR Final Safety Analysis Report and four separate reactor pulse comparisons using the CRANK system. Future applications of the CRANK system can provide independent determination of a pulsing research reactor with an unknown RKP ratio.