Home / Publications / Journals / Nuclear Technology / Volume 155 / Number 3
Nuclear Technology / Volume 155 / Number 3 / September 2006 / Pages 350-357
Technical Paper / Nuclear Plant Operations and Control / dx.doi.org/10.13182/NT06-A3767
Articles are hosted by Taylor and Francis Online.
This paper describes a new system for monitoring leaks in a steam generator. The new system extends the traditional 16N monitor to detect both the rate and the location of a leak. Because the transit time is different for radioactive 16N and 19O to travel from the reactor core via the hot bottom side, cold bottom side, or bend region of the U-tube in a steam generator to the gamma-ray detector, the new system uses the different transit times to identify the location of leaks. Specifically, the ratio S0 of 16N to 19O activities in the reactor core of a swimming pool reactor was calculated by combining the cross sections np(E) and
n
(E) with the neutron spectra
n(E). The ratio S1 of 16N to 19O activities in the measurement room was also calculated and measured by the high-purity germanium and NaI(Tl) detectors. The result of the calculation agrees with the measurement within an acceptable range.