American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 155 / Number 1

Chronic Dose Due to a Continuous Tritium Release Calculated by CAP88-PC and NORMTRI

Stacey F. Imboden, Thomas J. Overcamp

Nuclear Technology / Volume 155 / Number 1 / July 2006 / Pages 114-118

Technical Note / Radiation Protection / dx.doi.org/10.13182/NT06-A3750

CAP88-PC, Version 2.0, and NORMTRI, which are based on the Gaussian plume model, were used to estimate the chronic dose due to a continuous, ground-level, atmospheric release of tritium as tritiated water. For the same conditions the predictions of CAP88-PC were found to be higher by a factor of 3 or less than those of NORMTRI. The major differences are due to the use of higher dose coefficients in CAP88-PC and NORMTRI's method of calculating the tritium content of food.