American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 113 / Number 3

A Passive System for Long-Term Heat Removal in Advanced Light Water Reactors: Prototype Test Results and Analysis

Luca Galbiati, Luigi Mazzocchi, Paolo Vanini

Nuclear Technology / Volume 113 / Number 3 / March 1996 / Pages 338-345

Technical Paper / Heat Transfer and Fluid Flow / dx.doi.org/10.13182/NT96-A35213

The simplified boiling water reactor makes use of an isolation condenser (1C) submerged in a large water pool; following a postulated accident, the pool water boils off, releasing steam to the atmosphere and ensuring passive containment cooling for at least 3 days. A further improvement is the isolation condenser pool cooling system (ICPCS), proposed by ENEL /CISE. It makes use of reflux condensing heat exchangers directly connected to the pool gas space of the IC; noncondens-able gases can be vented during the earlier phase of operation by means of a water seal mechanism operating in a passive way. The expected benefits from the ICPCS are the elimination of constraints on the “grace period” duration and the possibility of avoiding an extended release of a visible and potentially radioactive steam plume. To verify the performance both at component and system level, an instrumented ICPCS prototype, operating with a thermal power scaling factor of ∼1:615, has been built and tested at CISE laboratories, both in steady and dynamic conditions. The experimental results confirm the capability of the tested ICPCS module to operate in a safe and passive way.