Home / Publications / Journals / Nuclear Technology / Volume 98 / Number 3
Nuclear Technology / Volume 98 / Number 3 / June 1992 / Pages 349-353
Technical Paper / Heat Transfer and Fluid Flow / dx.doi.org/10.13182/NT92-A34664
Articles are hosted by Taylor and Francis Online.
A simple rational-based model is developed to predict the pressure loss of a pressurized water reactor-type nonmixing vaned spacer grid. The total pressure loss is obtained by adding the form and friction losses. Elementary fluid-mechanical correlations are used to model each loss. The model reasonably predicts the available spacer grid loss data.