Home / Publications / Journals / Nuclear Technology / Volume 83 / Number 2
Nuclear Technology / Volume 83 / Number 2 / November 1988 / Pages 228-230
Technical Note / Technique / dx.doi.org/10.13182/NT88-A34165
Articles are hosted by Taylor and Francis Online.
The use of computerized tomography (CT) in nondestructive testing has been reported. An effort is made to develop higher order filters (convolving function) for CT machines employing filtered back projection reconstruction algorithms. These filters have been tested against a simulated image representing a simplified nuclear fuel bundle.