American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 48 / Number 2

Experimental Value of Percent Variation in Root-Mean-Square Ex-Core Detector Signal to the Core Barrel Amplitude Scale Factor

J. P. Thompson, G. R. McCoy, B. T. Lubin

Nuclear Technology / Volume 48 / Number 2 / April 1980 / Pages 122-127

Technical Paper / Reactor / dx.doi.org/10.13182/NT80-A32459

Ex-core neutron detector and core barrel-mounted accelerometer signals were used to determine the ratio of percent variation in the ex-core signal to core barrel amplitude. Based on these data, the nominal value, including uncertainties, is 1.60 ± 0.24%/mm (0.0407 ± 0.006%/mil). This result is in agreement with both predictions, based on a one-dimensional transport model, and previously reported data.