American Nuclear Society
Home

Home / Publications / Journals / Nuclear Technology / Volume 37 / Number 2

Oxygen Monitoring and Control in Boiling Water Reactor Plants

W. L. Pearl, W. R. Kassen, S. G. Sawochka

Nuclear Technology / Volume 37 / Number 2 / February 1978 / Pages 94-98

Technical Paper / Plant Water Chemistry / Reactor / dx.doi.org/10.13182/NT78-A31975

The variation of oxygen and hydrogen peroxide concentrations during steady-state and transient conditions were monitored at the Brunswick 2, Monticello, and Vermont Yankee boiling water reactors. Based on the findings, means for reducing the reactor water oxygen and hydrogen peroxide concentration during shutdown and startup transients were defined and demonstrated at Vermont Yankee.