Home / Publications / Journals / Nuclear Technology / Volume 36 / Number 1
Nuclear Technology / Volume 36 / Number 1 / November 1977 / Pages 74-78
Radiation Environments in Nuclear Reactor Power Plant / Reactor / dx.doi.org/10.13182/NT77-A31960
Articles are hosted by Taylor and Francis Online.
Safety-related equipment located inside the containment boundary of a pressurized water reactor must be qualified to withstand a radiation dose caused by a design-basis accident. Because of uncertainties in establishing the radiation dose, a margin of safety should be included. An analysis was performed of a core melt accident, a hypothetical accident, and a design-basis accident and a conclusion reached that a safety margin should be added to the loss-of-coolant accident dose.