Home / Publications / Journals / Nuclear Technology / Volume 131 / Number 3
Nuclear Technology / Volume 131 / Number 3 / September 2000 / Pages 354-378
Technical Paper / Radiation Biology and Medicine / dx.doi.org/10.13182/NT00-A3122
Articles are hosted by Taylor and Francis Online.
The Heavy Water Thermal Neutron Facility of the Kyoto University Research Reactor (KUR) was wholly updated in March 1996 mainly for neutron capture therapy. The performance as a neutron irradiation facility was improved using the epithermal neutron moderator of the aluminum-heavy water mixture (Al/D2O = 80/20 vol%), the neutron energy spectrum shifter of heavy water, and the thermal neutron filters of cadmium and boral plates. The clinical irradiation utilization under the full-power (5-MW) continuous KUR operation was realized employing both the radiation shielding system, consisting of the shielding door and irradiation room, and the remote carrying system for a patient. The safety and utility of the facility were improved due to the safety observation system.