Home / Publications / Journals / Nuclear Technology / Volume 5 / Number 4
Nuclear Technology / Volume 5 / Number 4 / October 1968 / Pages 275-282
Technical Paper and Note / dx.doi.org/10.13182/NT68-A28031
Articles are hosted by Taylor and Francis Online.
Studies conducted in the EBR-II at 20 kW and at full power, 45 MW, confirmed the usefulness of threshold reactions, such as 54Fe(n,p)54Mn and 58Ni(n,p)58Co, for fast-reactor dosimetry. Also, there are few neutrons (<1%) below 10−2 MeV in a fast-reactor core, and the (n,γ) reactions, such as 63Cu(n,γ)64Cu, become useful fast-flux monitors. Eighty percent of the core neutrons can cause (n,γ) reactions, while only 10% can cause (n,p) reactions. Results show that transport-theory calculations provide a good approximation to the spectrum in a fast reactor. Spectral-averaged cross sections for several EBR-II positions are presented.