American Nuclear Society
Home

Home / Publications / Journals / Nuclear Science and Engineering / Volume 198 / Number 2

Estimated 137Cs Radioactivity in the Gap Between the Top and Middle Covers at a Shield Plug in the Fukushima Daiichi Nuclear Power Station Unit 2

Hideo Hirayama, Kohei Iwanaga, Katsumi Hayashi, Kenjiro Kondo, Seishiro Suzuki, Zenko Yoshida

Nuclear Science and Engineering / Volume 198 / Number 2 / February 2024 / Pages 228-244

Research Article / dx.doi.org/10.1080/00295639.2023.2227824

Received:November 8, 2022
Accepted:June 7, 2023
Published:January 10, 2024

The contamination density of 137Cs deposited in the gap between the top and middle covers of the shield plug in the Fukushima Daiichi Nuclear Power Station Unit 2 was estimated using three types of measurement results. Owing to the extremely high dose rate on the entire operation floor, including the top of the shield plug, only remotely measured dose rates, such as ambient dose equivalent rates, were obtained using robots. Based on three types of measurements, significantly higher concentrations of 137Cs were observed than previously estimated. An estimation based on the measurements of the ambient dose equivalent rate inside the hole also demonstrated that the contamination density in the gap between the top and middle covers varied significantly at different positions of the cover. The results obtained will significantly aid in future decommissioning scenarios, and will be important for examining the progress of an accident.