Feynman-α Analysis Using BGO Gamma-Ray Detector in a University Training and Research Reactor

Masaki Goto, Tadafumi Sano, Kunihiro Nakajima, Takashi Kanda, Atsushi Sakon, Kengo Hashimoto

Nuclear Science and Engineering / Volume 197 / Number 8 / August 2023 / Pages 1814-1822

Technical papers from: PHYSOR 2022 / dx.doi.org/10.1080/00295639.2022.2143707

Received:July 28, 2022
Accepted:November 1, 2022
Published:July 7, 2023

Feynman-α analyses for a critical state and several subcritical states of the UTR-KINKI reactor have been carried out using two Bi14Ge3O12 (BGO) gamma-ray detectors free from radioactivation of the scintillator. As a statistical index of the analyses, the covariance-to-mean ratio of gamma counts between these detectors instead of the variance-to-mean ratio of each of the detectors is employed to get rid of a large negative correlation originating from the counting loss of a signal processing circuit. In the gate width dependence of the covariance-to-mean ratio measured at each reactor state, not only a familiar neutron-correlation component but also another small positive correlation between prompt gammas can clearly be observed. The prompt-neutron decay constant α determined considering the positive gamma correlation agrees very well with that obtained from a conventional Feynman-α analysis based on neutron detection. Neglecting the gamma correlation term, the decay constant is much overestimated with an increase in subcriticality, and the maximum overestimation reaches about 24% at a shutdown state with a subcriticality of 1.49%Δk/k.