American Nuclear Society
Home

Home / Publications / Journals / Nuclear Science and Engineering / Volume 196 / Number 9

Blind Benchmark Exercise for Spent Nuclear Fuel Decay Heat

Peter Jansson, Martin Bengtsson, Ulrika Bäckström, Francisco Álvarez-Velarde, Dušan Čalič, Stefano Caruso, Ron Dagan, Luca Fiorito, Lydie Giot, Kevin Govers, Augusto Hernandez Solis, Volker Hannstein, Germina Ilas, Marjan Kromar, Jaakko Leppänen, Marita Mosconi, Pedro Ortego, Rita Plukienė, Arturas Plukis, Anssu Ranta-Aho, Dimitri Rochman, Linus Ros, Shunsuke Sato, Peter Schillebeeckx, Ahmed Shama, Teodosi Simeonov, Alexey Stankovskiy, Holly Trellue, Stefano Vaccaro, Vanessa Vallet, Marc Verwerft, Gašper Žerovnik, Anders Sjöland

Nuclear Science and Engineering / Volume 196 / Number 9 / September 2022 / Pages 1125-1145

Technical Paper / dx.doi.org/10.1080/00295639.2022.2053489

Received:October 5, 2021
Accepted:March 11, 2022
Published:July 29, 2022

The decay heat rate of five spent nuclear fuel assemblies of the pressurized water reactor type were measured by calorimetry at the interim storage for spent nuclear fuel in Sweden. Calculations of the decay heat rate of the five assemblies were performed by 20 organizations using different codes and nuclear data libraries resulting in 31 results for each assembly, spanning most of the current state-of-the-art practice. The calculations were based on a selected subset of information, such as reactor operating history and fuel assembly properties. The relative difference between the measured and average calculated decay heat rate ranged from 0.6% to 3.3% for the five assemblies. The standard deviation of these relative differences ranged from 1.9% to 2.4%.