American Nuclear Society
Home

Home / Publications / Journals / Nuclear Science and Engineering / Volume 193 / Number 12

A Directional Detector Response Function for Anisotropic Detectors

Cihangir Celik, Douglas E. Peplow, Gregory G. Davidson, Mathew W. Swinney

Nuclear Science and Engineering / Volume 193 / Number 12 / December 2019 / Pages 1355-1370

Technical Paper / dx.doi.org/10.1080/00295639.2019.1631028

Received:May 3, 2019
Accepted:June 9, 2019
Published:November 13, 2019

For a radiation detector that is not isotropic, a directional detector response is needed to accurately account for the variation in a detector’s behavior depending on the incoming particle direction. The concept of the detector response function has been extended to include particle direction using a set of pregenerated detector responses based on the orientation of the incoming radiation and the detector. This directional detector response function (DDRF) then can be applied to the flux and current tallies computed by a Monte Carlo simulation. Validation of the new approach has been done by comparing simulated count rates processed with the DDRF to measured count rates taken with a 5.08 × 10.16 × 40.64-cm NaI(Tl) detector. The comparisons show that the applied method produces good agreement with both background and source measurements with a 137Cs source. Furthermore, separation of the detector response generation from Monte Carlo particle transport calculations provides greater flexibility in locating single or multiple detectors without any interference in the model and also enables simulation of various models using the same detector response without the need for generating additional detector responses if the same detector is being used.