American Nuclear Society
Home

Home / Publications / Journals / Nuclear Science and Engineering / Volume 181 / Number 3

Evaluation of Spatial Correction Factors for BRAHMMA Subcritical Assembly

Shefali Bajpai, Tushar Roy, Nirmal Ray, Yogesh Kashyap, Mayank Shukla, Tarun Patel, Amar Sinha

Nuclear Science and Engineering / Volume 181 / Number 3 / November 2015 / Pages 361-367

Technical Paper / dx.doi.org/10.13182/NSE14-137

First Online Publication:August 31, 2015
Updated:December 11, 2015

The reactivity measurement in a subcritical assembly using the area ratio method is affected by the detector location and needs to be corrected for spatial dependence. One of the approaches to calculate the spatial correction factor is based on steady-state numerical simulation as proposed by Bell and Glasstone. This paper discusses the evaluation of the spatial correction factor for the BRAHMMA (BeO Reflected And HDPe Moderated Multiplying Assembly) subcritical assembly, India. The factors have been used to correct experimentally measured reactivity values from the area ratio method at different locations inside the core.