Nuclear Science and Engineering / Volume 19 / Number 3 / July 1964 / Pages 363-366
Technical Paper / dx.doi.org/10.13182/NSE64-A20970
Articles are hosted by Taylor and Francis Online.
An improved thermal homogenization procedure has been developed for fuel regions containing a finite number of thin slab subcells. This procedure applies a “non-cell” correction factor to the usual subcell flux-volume weighted constants, resulting in improved leakages to or from exterior environments adjacent to the homogenized fuel region. The form of the non-cell factor is dictated by a neutron free-flight argument.