Thermal-Neutron Capture Cross Section and Resonance Capture Integral of Ce140 and Effective Capture Cross Section of Ce141

P. M. Lantz, C. R. Baldock and L. E. Idom

Nuclear Science and Engineering / Volume 20 / Number 3 / November 1964 / Pages 302-306

Technical Paper / dx.doi.org/10.13182/NSE64-A19573

The thermal-neutron capture cross section of Ce140 and its resonance capture integral, measured by an activation method, have been found to be 0.59 ± .06 barns and 0.48 ± .05 barns, respectively. The effective capture cross section of Ce141 in the Materials Testing Reactor was found to be 29 ± 3 barns. This value was determined by mass analysis for the neutron-induced Ce142.