American Nuclear Society
Home

Home / Publications / Journals / Nuclear Science and Engineering / Volume 19 / Number 4

The ‘n’ on ‘p’ Silicon Solar-Cell Gamma-Ray Dose-Rate Meter

A. C. Muller, F. X. Rizzo, and L. Galanter

Nuclear Science and Engineering / Volume 19 / Number 4 / August 1964 / Pages 400-405

Technical Paper / dx.doi.org/10.13182/NSE64-A18995

The recently developed ‘n’ on ‘p’ type silicon solar cell has been evaluated for application as a high-level gamma-radiation dose-rate meter. The solar-cell ionization current was found to be a linear function of dose rate in a range from 102 to 107 rads per hour. A degradation rate of approximately one per cent per megarad was measured after stabilization with twenty megards of cobalt-60 gamma radiation. The system has proven to be stable over long periods of time. Temperature dependence corrections have been found to be 0.2 per cent per degree centigrade between 0 and 60 degrees centigrade.