American Nuclear Society
Home

Home / Publications / Journals / Nuclear Science and Engineering / Volume 89 / Number 1

Neutron Capture Measurements on Fission Product 107Pd

R. L. Macklin

Nuclear Science and Engineering / Volume 89 / Number 1 / January 1985 / Pages 79-86

Technical Paper / dx.doi.org/10.13182/NSE85-A17885

Neutron capture measurements were made on a sample of fission product palladium at the Oak Ridge Electron Linear Accelerator time-of-flight facility. One hundred thirty resonance peaks were parameterized up to 3.5 keV and the average cross section from 3 to 600 keV was derived. The data exceed the ENDF/B-Vevaluation by ∼25% in the 3- to 300-keV range but drop steeply below it at higher energies where neutron inelastic-scattering competition becomes important. The Maxwellian average cross section for kT = 30 keV is calculated as 1.34 ± 0.06 b, and the dilute resonance capture integral as 108.1 ± 4.3 b.