Fusion Science and Technology / Volume 47 / Number 1T / January 2005 / Pages 333-335
Technical Paper / Open Magnetic Systems for Plasma Confinement / dx.doi.org/10.13182/FST05-A681
Articles are hosted by Taylor and Francis Online.
Recently GOL-3 has been reconfigured to a multimirror trap with improved confinement and high ion temperature. A dense plasma is created with a life time in the millisecond range. BTI neutron bubble detectors, a stilbene scintillation crystal, a BC501A liquid scintillator, and a silver-activation counter have been used for measurements of the neutron emission from GOL-3. The results are in agreement with charge-exchange (CX), spectral broadening of the D line, and diamagnetic measurements.