Fusion Science and Technology / Volume 77 / Number 1 / January 2021 / Pages 9-18
Technical Paper / dx.doi.org/10.1080/15361055.2020.1831872
Articles are hosted by Taylor and Francis Online.
As part of the recovery project of the National Spherical Tokamak Experiment–Upgrade (NSTX-U), the divertor plasma-facing components (PFCs) were redesigned to handle significantly higher heat fluxes and longer pulse lengths than NSTX. The design process resulted in a castellated, graphite PFC tile. To verify the thermal performance of this design, dedicated electron beam, high heat flux (HHF) testing was carried out on a de-optimized mock-up PFC target. These tests demonstrated that the tile design is itself robust to large, localized thermal gradients. No mechanical damage to the mock-up was observed during HHF testing, though the actual PFC tile mechanical tie-down was not tested. Rather, when the surface temperature exceeded the sublimation temperature of graphite, carbon blooms from the mock-up tile surface were observed. This resulted in 1 to 2 mm of surface material ablating from the mock-up after repeated, highly localized electron beam exposures.