Design of a Medium-Scale Aerosol Source for ITER Safety Studies

W.J. Carmack, J.E. O'Brien, G.R. Smolik, K.A. McCarthy

Fusion Science and Technology / Volume 30 / Number 3P2B / December 1996 / Pages 1448-1452

Safety and Environment / dx.doi.org/10.13182/FST96-A11963152

Published:February 9, 2018

The Fusion Aerosol Source Test (FAST) facility has been constructed to produce and measure aerosol material from 316 SS under a wide range of accident conditions. Details of the design and fabrication of the facility are presented including aerosol production and measurement equipment, effluent control, and data analysis. Preliminary testing has been completed and results from these preliminary tests are presented.