High Heat Flux Testing and Post-Mortem Observation of Small-Scale ITER First Wall Mock-Up Made by HIP Joining

Moriyasu Kanari, Toshihisa Hatano, Satoshi Sato, Kazuyuki Furuya, Toshimasa Kuroda, Mikio Enoeda, Hideyuki Takatsu

Fusion Science and Technology / Volume 34 / Number 3P2 / November 1998 / Pages 882-886

Fusion Blanket and Shield Technology (Poster Session) / dx.doi.org/10.13182/FST98-A11963724

Published:February 8, 2018

A small scale first wall mock-up fabricated by HIP bonding of DS-Cu plates, internal SS cooling tubes and a SS base plate has been tested with heat fluxes of 5–7 MW/m2 up to 2500 cycles in total resulting in no identification of exfoliation at the joints and no degradation of heat removal performance. Post-mortem observations of the HIP bonded interfaces and hardness tests around the bonded interface were performed. With these detailed observations and tests, the high integrity of the HIP bonded interfaces was confirmed.