Recycling Control for LHD Using Carbon Sheet PUMP

Hajime Suzuki, Akio. Sagara, Nobuyoshi Ohyabu, Osamu Motojima

Fusion Science and Technology / Volume 27 / Number 3T / April 1995 / Pages 523-526

Plasma Particle and Heat Control Studies / dx.doi.org/10.13182/FST95-A11962955

Published:February 8, 2018

Carbon Sheet Pump(CSP) has been proposed to be installed on the vacuum vessel wall of the Large Helical Device(LHD) in order to reduce the hydrogen recycling and improve the energy confinement.

The CSP of C/C composite with temperature below 200 °C can pump high energy hydrogen particles such as charge exchange fast neutrals by trapping them. The saturated hydrogen particles can be removed simply by heating the carbon sheet above 800 °C. One of the requirement on the CSP design for LHD is that the temperature of the vacuum vessel must be maintained to be below 70 °C to avoid excessive heat flux to the LHD superconducting magnet system.

The first design of CSP for LHD is presented, and a successful demonstration of heating the CSP carried out.