American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 26 / Number 3P2

Assessment of First Wall Lifetime in D-3He and D-T Reactors with Impact on Reactor Availability

M. E. Sawan, I. N. Sviatoslavsky

Fusion Science and Technology / Volume 26 / Number 3P2 / November 1994 / Pages 1141-1145

Fusion Power Reactor, Economic, and Alternate Concept / Proceedings of the Eleventh Topical Meeting on the Technology of Fusion Energy New Orleans, Louisiana June 19-23, 1994 / dx.doi.org/10.13182/FST94-A40307

The neutron yield in a D-3He reactor is much lower than that in a D-T reactor of equivalent power. Therefore, the rate of neutron damage and gas production in the first wall of D-3He reactors is lower by more than an order of magnitude. Whereas different structural materials proposed for use in commercial fusion reactors will last the reactor lifetime of 30 full power years in a D-3He reactor, frequent replacement of the first wall and blanket will be required during the lifetime of a D-T power reactor. The blanket modules may require 30 replacements depending on the material used and the maximum allowable damage level. The down time required for replacement of the first wall and blanket in a D-T reactor will impact the reactor availability and consequently the cost of electricity. It appears that a D-3He reactor should have a 10% advantage in availability over a D-T reactor.