American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 26 / Number 3P2

Spectrum Weighting Function Method for In-Situ Fast Neutron and Gamma-Ray Response Measurements in Fusion Integral Experiments with an NE213 Scintillation Detector

Yukio Oyama, Kazunori Sekiyama, Hiroshi Maekawa

Fusion Science and Technology / Volume 26 / Number 3P2 / November 1994 / Pages 1098-1102

Fusion Blanket, Shield, and Neutronic Technology / Proceedings of the Eleventh Topical Meeting on the Technology of Fusion Energy New Orleans, Louisiana June 19-23, 1994 / dx.doi.org/10.13182/FST94-A40300

Spectrum weighting function method with an NE213 scintillation detector has been applied to measurements of integral parameters such as tritium production rate from 7Li, in-system neutron integral flux and gamma-ray heating rate in fusion neutronics experiments. The NE213 scintillation detector can separate neutron and gamma-ray responses from each other, and those detector responses give energy information of both neutron and photon from recoil-proton and recoil-electron spectra, respectively. Connecting these energy responses with the energy responses of the nuclear parameters of interest such as 7Li(n,n′α)3T reaction cross section, step function response of neutron energy and mass energy absorption coefficiency of gamma-ray, the corresponding nuclear parameters are obtained indirectly. The conversion method from the raw response of the detecter is introduced by a spectrum weighting function.