Shielding Analysis for the Horizontal X-ray Imaging System on the TFTR

S. L. Liew, L. P. Ku, J. Kolibal, K. W. Hill

Fusion Science and Technology / Volume 8 / Number 1P2A / July 1985 / Pages 1020-1025

Shielding Neutronic / Proceedings of the Sixth Topical Meeting on the Technology of Fusion Energy (San Francisco, California, March 3-7, 1985) / dx.doi.org/10.13182/FST85-A40167

Intense neutron and gamma radiation will accompany the reactor like DD and DT plasmas that are planned to be generated on the TFTR. Since many plasma diagnostic systems use detectors that are sensitive to neutrons and gamma-rays to various degrees, local shielding will be required to achieve acceptable signal to noise ratios during those high power operations. In this paper, we analyze the shielding problems related to the horizontal x-ray imaging system.