American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 8 / Number 1P2B

Low Activation Diagnostic Equipment Design Studies

G. R. Hopkins, E. T. Cheng, R. K. Fisher

Fusion Science and Technology / Volume 8 / Number 1P2B / July 1985 / Pages 1402-1407

Environment and Safety / Proceedings of the Sixth Topical Meeting on the Technology of Fusion Energy (San Francisco, California, March 3-7, 1985) / dx.doi.org/10.13182/FST85-A39963

The low activation fusion concept has been applied to the diagnostic equipment in a fusion reactor. The components where fabrication from low activation materials is feasible have been identified. Other systems where higher activation elements are required can have their activation reduced by design approaches which include shielding and operation only in low flux regions of the reactor. Some components will not operate in a high flux so activation is not a major concern. This low activation diagnostic equipment study completes a series of low activation studies where all the components in a fusion power reactor have now been evaluated. It is concluded that a completely low activation fusion reactor is feasible with all components meeting the functional requirements. This provides an environmentally benign energy source with a high confidence level in meeting safety criteria in operation, maintenance and waste disposal.