Fusion Science and Technology / Volume 8 / Number 1P2B / July 1985 / Pages 1284-1288
Impurity Control and Vacuum Technology / Proceedings of the Sixth Topical Meeting on the Technology of Fusion Energy (San Francisco, California, March 3-7, 1985) / dx.doi.org/10.13182/FST85-A39945
Articles are hosted by Taylor and Francis Online.
Mixtures of hydrogen isotopes, primarily deuterium (D2), protium-deuterium (HD), and protium (H2) must be pumped by the vacuum system in the Mirror Fusion Test Facility at Lawrence Livermore National Laboratory. In this study, we used argon as an adsorbent for cryopumping these isotopes at 4.2 K and found that deuterium will displace already adsorbed protium. Thus, when we pump mixtures of the two, sufficient argon must be supplied to adsorb both species. We also found that without argon, deuterium will cryotrap protium in accord with Raoult's law.