American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 15 / Number 2P2B

Design Development and Construction of the RFX Field Shaping Winding

G. Chitarin, M. Guarnieri, A. Stella

Fusion Science and Technology / Volume 15 / Number 2P2B / March 1989 / Pages 1032-1038

Magnet Engineering, Design and Experiments — II / dx.doi.org/10.13182/FST89-A39828

The paper describes the development work on the design and the manufacture of the RFX Field Shaping Winding, from the preliminary analysis and the tests on prototypes to the final design. The winding consists of 16 coils, with 24 copper turns each and of diameters up to 5.5 m. The maximum current is 6.25 kA and the maximum voltage to earth is 35 kV. Each coil is supported in 24 radial locations and the electrodynamic load on a single coil is approximately 40 kN/m in normal operation. Fiberglass impregnated with epoxy resin, reinforced in places with polymide tape, has been used for the insulation. The high levels of the electrical and mechanical strength specified present conflicting constraints, which have required some care in the structural design and in the definition of insulation system and impregnation technology. Although the use of copper coils with this kind of insulation may seem obvious and well established, indeed the stringent operational requirements have posed a number of problems which have demanded extensive work on the design and prototype development.