Fusion Science and Technology / Volume 68 / Number 1 / July 2015 / Pages 178-184
Technical Note / Open Magnetic Systems 2014 / dx.doi.org/10.13182/FST14-877
Articles are hosted by Taylor and Francis Online.
In GAMMA 10/PDX, divertor simulation studies have been started as a new research plan by using end-loss plasma flux at the end-mirror region. A divertor simulation experimental module (D-module) was installed in the west end-cell. Here we introduce a novel microwave interferometer system with a phase imaging method, and all the crucial components are designed and tested. Finally, we tested the interferometer system using a Teflon plate in substitution for plasma. In order to improve the system accuracy, the phase detection circuit was modified and the phase difference of each channel was verified.