Development of a Wide-range Tritium-concentration Detector

Fu Jun, Liao Zhe, Wang Lei, Li Shicheng, Song Jiangfeng, Luo Deli

Fusion Science and Technology / Volume 67 / Number 2 / March 2015 / Pages 336-338

Proceedings of TRITIUM 2013 / dx.doi.org/10.13182/FST14-T24

First Online Publication:January 19, 2015
Updated:February 27, 2015

According to the requirements of the tritium related systems of the TBM for monitoring the on-line tritium concentration, a wide-range tritium-concentration detector has been developed to measure the tritium concentration in the range of 104 Bq/ml &sim 5×108 Bq/ml. Correspondingly, the minimum weak current which the detector could be measured is 10−14 A. The performances of the background current and the current response linearity of the prototype have been tested.