Fusion Science and Technology / Volume 30 / Number 3P1 / December 1996 / Pages 383-385
Technical Note / Nuclear Reaction in Solid / dx.doi.org/10.13182/FST96-A30741
Articles are hosted by Taylor and Francis Online.
Neutron and proton emission due to possible solid state fusion events is monitored from a palladium sample loaded with deuterium gas to atomic fractions up to 0.7. Most of the experimental runs show no detectable activity above background rates, indicating a fusion rate <2.7 × 10−22 s−1/deuterium-deuterium (D-D) pair. Two brief excursions by the proton counter might indicate a temporary rate of 3.5 × 10−21 s−1/D-D pair.