American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 28 / Number 3P2

Tritium Stripping in a Nitrogen Glove Box Using Palladium/Zeolite and SAES ST 198

J. E. Klein, J. R. Wermer

Fusion Science and Technology / Volume 28 / Number 3P2 / October 1995 / Pages 1532-1539

Tritium Waste Management and Discharge Control / Proceedings of the Fifth Topical Meeting on Tritium Technology In Fission, Fusion, and Isotopic Applications Belgirate, Italy May 28-June 3, 1995 / dx.doi.org/10.13182/FST95-A30630

Glove box clean-up experiments were conducted in a nitrogen glove box using palladium deposited on zeolite (Pd/z) and a SAES St 198™ getter as tritium stripping materials. Protium/deuterium samples spiked with tritium were released into a 620 liter glove box to simulate tritium releases in a 10, 500 liter glove box. The Pd/z and the SAES St 198™ stripper beds produced a reduction in tritium activity of approximately two to three orders of magnitude and glove box clean-up was limited by a persistent background tritium activity level. Attempts to significantly reduce the glove box activity to lower levels without purging were unsuccessful.