American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 25 / Number 2

Subignited, ITER-Like Designs—A Question of Confinement Margin

J. D. Galambos, L. John Perkins

Fusion Science and Technology / Volume 25 / Number 2 / March 1994 / Pages 176-181

Technical Paper / Fusion Reactor / dx.doi.org/10.13182/FST94-A30266

If the next-step International Thermonuclear Experimental Reactor (ITER) is designed to operate at finite energy multiplication (Q ∼ 10 to 20), as opposed to ignition (Q ∼ ∞), appreciable reductions in size and cost will result. Ignition will be attainable in such a “high-Q targeted” device under slightly enhanced confinement conditions. For example, with the nominal design guidelines from the ITER Conceptual Design Activity (CDA), designing for Q = 15 instead of ignition results in ∼20% savings in size and cost. Ignition would still be achievable in such a reduced-size device if the L-mode energy confinement enhancement factor (i.e., H factor) is ∼15% higher than the assumed nominal value of 2.0. This size/cost impact is large compared to other sensitivities, and the range of H-fact or improvement needed to recoup ignition is small compared to the uncertainty in the confinement scalings themselves.