American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 24 / Number 1

Derivation of Nuclear Parameters for Delayed Neutron Detector Measurements for D-D and D-T Plasma Operation at the Joint European Torus

Maurizio Angelone

Fusion Science and Technology / Volume 24 / Number 1 / August 1993 / Pages 37-49

Technical Paper / Experimental Device / dx.doi.org/10.13182/FST93-A30173

The first attempt to calculate the parameters for 238U and 232Th used in the analysis of delayed neutron counter measurements of the total neutron yield from deuterium-tritium (D-T) plasmas is described. The nuclear theory of systematics is employed, together with nuclear data from the literature. As a check on the methods used, the delayed neutron parameters were also calculated f or deuterium-deuterium plasma conditions; the resulting neutron yields agreed within ± 7% with the results obtained using the experimentally calibrated delayed neutron counter assemblies. After the calculations were completed, the first D-T plasma experiment was performed at the Joint European Torus (JET). Delayed neutron measurements were made using 232Th samples. The calculated delayed neutron parameters gave neutron yields that agreed within ±8% with those obtained with conventional activation methods, using iron and silicon samples.