American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 23 / Number 2

Measurements of Excess Heat from a Pons-Fleischmann-Type Electrolytic Cell Using Palladium Sheet

Edmund Storms

Fusion Science and Technology / Volume 23 / Number 2 / March 1993 / Pages 230-245

Technical Note on Cold Fusion / dx.doi.org/10.13182/FST93-A30151

Two pieces of palladium sheet similar to that used by Takahashi were loaded with deuterium in a Pons-Fleischmann-type electrolytic cell, and heat production was measured. One sheet produced a steady increase in excess power that reached 7.5 W (20% of input power) before the study was interrupted. A second similar sheet from a different batch of palladium did not produce any measurable excess power. There were differences in the loading behavior, the maximum stoichiometry, and the presence of excess volume in the deuteride made from these materials. The first sheet contained 0.8% excess volume after having been deloaded from its maximum deuterium/palladium (D/Pd) ratio of 0.82 to 0.73, and the second sheet contained 13.5% excess volume while at its maximum ratio of 0.75. The high excess volume in the latter case is an indication of internal escape paths that reduce the required high D/Pd ratio.