Fusion Science and Technology / Volume 21 / Number 3P2A / May 1992 / Pages 1639-1643
Plasma Engineering / dx.doi.org/10.13182/FST92-A29955
Articles are hosted by Taylor and Francis Online.
There is considerable demand in the scientific community for a neutron generator with an output of 105–106 n/s that can be turned on or off, emits fusion neutrons, is self-calibrating, and can offer portable operation [1,2]. This paper will describe how an IEC-based neutron generator could satisfy these demands. Experimental data and modeling is presented for operation to the 105 n/s range. Direct extrapolation of the results indicate that with modest extension of operating parameters operation can be achieved in the 106–107 n/s range; with more aggressive modifications operation in the 108–10 n/s range can be possible.