Activation Products Effluents Evaluation for ITER

Y. Seki, H. Noguchi, K. Maki, H. Iida, S.J. Piet

Fusion Science and Technology / Volume 19 / Number 3P2B / May 1991 / Pages 1831-1836

Neutronic / Proceedings of the Ninth Topical Meeting on the Technology of Fusion Energy (Oak Brook, Illinois, October 7-11, 1990) / dx.doi.org/10.13182/FST91-A29610

Inventories, release amount, and resulting site boundary dose are evaluated for the possible activation products effluents from ITER. They are activated corrosion products in the cooling water of the primary cooling system, activation of the cooling water itself, the air or inert gas surrounding penetration ducts, high voltage insulating gas for the neutral beam injector, and activated dust in the plasma chamber. The site boundary dose for the public due to the atmospheric effluents of activation products is evaluated to be ∼2 μSv/a which is well below the ITER design target of 50 μSv/a for the sum of tritium and activation products atmospheric effluents.