American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 18 / Number 1

Neutron Monitoring and Related Measurements During Electrolysis of Heavy Water with Palladium and Titanium Cathodes: Activity Report

A. Foglio Para, V. Sangiust, P. L. Cavallotti, U. Ducati, P. F. Bortignon

Fusion Science and Technology / Volume 18 / Number 1 / August 1990 / Pages 131-135

Technical Note / Cold Fusion / dx.doi.org/10.13182/FST90-A29238

Results obtained in more than 100 electrolysis experiments of D2O with palladium and titanium cathodes, characterized by continuous high-efficiency neutron monitoring, are reported. In two runs with palladium cathodes, anomalous counts were observed that could not be rejected as evident spurious signals. In one of the two runs, anomalous counts were simultaneous with deformation of the palladium cathode. The two events are reported as candidate events of neutron emission. Moreover, in 2 (of 30) experiments with pulsed current, a statistically significant difference between counts in the charging and in the relaxation phases was observed. Some tritium measurements in the electrolyte solution were carried out, with no evidence of tritium contamination over the natural content. Analyses of the gases from the cathodes revealed the presence of species with masses of five and six, which could be attributed to DDH and D3 molecules.