American Nuclear Society
Home

Home / Publications / Journals / Fusion Science and Technology / Volume 10 / Number 3P2A

In-Vacuum Cyclic Fatigue Behavior of Vanstar-7 at Elevated Temperatures

K. C. Liu

Fusion Science and Technology / Volume 10 / Number 3P2A / November 1986 / Pages 1006-1011

Fusion Materials—Properties and Behavior / Proceedings of the Seveth Topical Meeting on the Technology of Fusion Energy (Reno, Nevada, June 15–19, 1986) / dx.doi.org/10.13182/FST86-A24866

Unirradiated Vanstar-7 alloy was tested in fatigue at room temperature, 550°, and 650°C, respectively, in high vacuum below 10−5 Pa. The test data were analyzed and compared with those of V-15Cr-5Ti and 20% cold-worked type 316 stainless steel tested under the same condition. Results show that the fatigue resistance of Vanstar-7 is in general somewhat lower than that of V-15Cr-5Ti. The low fatigue performance for Vanstar-7 at the elevated temperatures in the high cycle range may be attributable to thermal creep damages because Vanstar-7 is less creep resistant than V-15Cr-5Ti. However, Vanstar-7 exhibits superior fatigue resistance compared with the stainless steel in the low strain range below 0.5% strain.