Neutron Field Characteristics in a Concrete Cavity Having a DT Neutron Source

Y. Oyama, Y. Ikeda, T. Mori, M. Nakagawa, T. Nakamura, H. Maekawa

Fusion Science and Technology / Volume 10 / Number 3P2A / November 1986 / Pages 585-590

Fusion Nucleonics Experiments / Proceedings of the Seveth Topical Meeting on the Technology of Fusion Energy (Reno, Nevada, June 15–19, 1986) / dx.doi.org/10.13182/FST86-A24807

Neutronic parameters in a small room surrounded by the thick concrete wall have been measured and compared with the Monte Carlo calculations. The experimental setups were designed appro-Oriately for each neutronic parameter, and a variety of measuring techniques were applied. The comparisons of both measured and calculated results showed excellent agreement.