The Determination of Deuterium and Tritium in Effluent Wastewater by Pulsed Nuclear Magnetic Resonance Spectroscopy

A. Attalla, J. C. Birkbeck

Fusion Science and Technology / Volume 8 / Number 2P2 / September 1985 / Pages 2467-2470

Material Property and Tritium Control / Proceedings of the Second National Topical Meeting on Tritium Technology in Fission, Fusion and Isotopic Applications (Dayton, Ohio, April 30 to May 2, 1985) / dx.doi.org/10.13182/FST85-A24649

A pulsed nuclear magnetic resonance (NMR) procedure was developed for the quantitative determination of deuterium and tritium in radioactive, effluent, wastewater to aid in the design of an efficient combined electrolytic/catalytic exchange system for the recovery of these hydrogen isotopes. The deuterium and tritium NMR signals were observed at 9.210 and 45.7 MHz, respectively. Ten different effluent water samples were analyzed for deuterium and tritium to establish base-line data for the preparation of standard reference samples. The hydrogen isotope concentrations ranged from 0.11 to 2.40 g deuterium and from 2.0 to 21.0 mg tritium per liter of processed sample. The standard deviation of the hydrogen isotope determinations is ±0.017 g deuterium and ±0.06 mg tritium per liter of processed effluent water. In the future, the effectiveness of specially prepared and analyzed (calorimetry) effluent samples as tritium standards will be investigated. *Mound is operated by Monsanto Research Corporation for the U. S. Department of Energy under Contract No. DE-AC04-76DP00053.